• RaoulDookEnglish
    arrow-up
    63
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Yes I have 2 of them.

    FYI you should turn over each of your fire extinguishers at least once every 6 months to keep them working right. That means pick it up, rotate it upside-down, and let the stuff inside slide to the top, then turn it back over. I learned this from a fire inspector that I had to guide through a datacenter once.

    • NuXCOM_90Percent
      arrow-up
      26
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      It really depends on the kind of fire extinguisher as to whether that matters. That said, my understanding is that if it is a dry powder that has settled it would be visible on the pressure gauge.

      Really, that is about actually checking the pressure gauge every six months. If you tell someone to look, they never will. If you tell someone they have to do something, they might. Its the same logic behind “testing” a smoke alarm. The electronics are simple enough that you would REALLY need to try to damage them (and they are set up to piss you off with incessant beeping when failing anyway). But by pushing the button every six months, you actually check if there is a battery in it and so forth. Rather than hearing it beep in the morning, telling yourself you’ll fix it when you get home, and never doing so.

      • RememberTheApollo
        arrow-up
        4
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        How does powder settling affect a pressure gauge? There has been no change to the internal pressure of the vessel, the change loose vs compacted powered will not change the volume of materials inside the extinguisher. The only way the pressure should change is if there’s a leak.

        • NuXCOM_90Percent
          arrow-up
          1
          arrow-down
          2
          ·
          9 months ago
          link
          fedilink

          It very much depends on the specific materials which is why it is a “let’s not get into this and just say ‘better safe than sorry’” situation but: Even if the powder is settled, it is going to almost immediately get kicked up and re-mixed once you start spraying. Probably don’t test this for yourself for obvious reasons, but that is why a “fresh” can of spray paint will basically always work. It might not be even for the first few sprays but it rapidly becomes even.

          Over simplifying (because molecular dynamics and shit) but think of it like a really crowded room. You basically can’t sit down, let alone lie down, if it is crowded enough. And even if you try, someone will nudge you (or kick you) and you will get going.

          As the pressure decreases, the settled powder is less likely to be disturbed and you are more likely to wake up from your nap wondering why nobody else is waiting for the new Star Wars with you. And that is why paint cans have the shaker and so forth.

          So if your fire extinguisher has settled/compacted to the point that it is not viable? It is almost guaranteed to be because of a pressure leakage and that would be reflected on the gauge.

          Now, there is probably some variant where this can happen regardless. But that would be a bad product anyway because these need to work even if nobody can ever be bothered to find the key to the glass box.

          • RememberTheApollo
            arrow-up
            1
            arrow-down
            0
            ·
            9 months ago
            link
            fedilink

            Your logic is not correct. Powder and people are not the same. Volume is volume, and particles of fire retardant are not changing size or quantity. If pressure drops substantially in an extinguisher, it’s leaking.

            A can of fresh spray paint works because the seals are all still good and the nozzle isn’t clogged, and cans of used spray paint can leak out pressure or have the nozzle or other plumbing jammed up with dried spray paint.

            • MrShankles
              arrow-up
              2
              arrow-down
              0
              ·
              9 months ago
              edit-2
              9 months ago
              link
              fedilink

              You’re right, the pressure gauge shouldn’t change without a leak or temperature change (Boyle’s Law and such). But it’s hard to have a 100%, no-leak extinguisher. There’s plenty of points of failure to keep the thing pressurized, and the leak could be imperceptible (over months) or a rapid failure

              And you wanna keep contents from settling as well, so you don’t just spray gas when trying to use it. So you mix it a bit and inspect the gauge every so often, because you don’t want it to fail when you need it most

              Ideally, it shouldn’t lose pressure. But also ideally, you don’t have a fire that requires an extinguisher in the first place

              But yes, you’re right on that one. “Settling” of the fire-retardent wouldn’t cause a pressure change. It’s just part of the safety inspection to check the gauge as well as to “mix” it keeping it ready to go

    • spacecowboy
      arrow-up
      4
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Those in the biz call it “fluffing” the FE.

  • Bonehead
    arrow-up
    42
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    I have 3. 2 are still pressurized. One was used last night.

    A note to everyonedo your welding before you paint and undercoat, or at least wait for it to dry fully first.

    • nick
      arrow-up
      14
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Hope it all turned out ok! You’re posting so clearly you survived

      • Bonehead
        arrow-up
        10
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        Everything is fine. I was welding in the outer rocker when it ignited. It was a brief flash and then it went out. I only used the fire extinguisher because I saw smoke coming from the seatbelt hole near the top of the door. I figured better safe than sorry. Of course now the inside of the rocker that I can’t get to anymore is covered in white powder, but at least it’s kinda fireproof now.

    • UristEnglish
      arrow-up
      2
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Maybe I am just projecting here, but I believe the average Lemmy user to be too much of a nerd to be welding in their free time. Is it possible to be both Bonehead?

      • Bonehead
        arrow-up
        3
        arrow-down
        0
        ·
        9 months ago
        edit-2
        9 months ago
        link
        fedilink

        You’re projecting. I weld because I’m a nerd. This job is just helping out a buddy, but before that I was welding a new mount for my trailer hitch snow plow that I built a few years ago. And this summer I want to build a remote control lawnmower which is going to involve a lot of welding, plus some code to reprogram the hoverboards that I bought for that project. The real challenge there will be adding basic intelligence with a Raspberry Pi so that it will mow the lawn itself. But that’s a few years away, since I still need to build it first. And that starts with welding the frame.

        It’s not really possible to be both, since one is merely a tool that satisfies the needs of the other. Nerd always takes precedence

  • Milk_Sheikh
    arrow-up
    29
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Piggybacking on this PSA to remind everyone;

    • Attack the base of the fire, where the fuel source is. You need to break the fire triangle to stop the reaction, and drowning out oxygen is the easiest way.
    • Each rated pound of fire extinguisher yields approximately one second of use. They go quickly when you’re fighting any fire, and even small fires fight back. 5lb is the minimum imo, look at any commercial setting where OSHA applies and it’s big 10-20lb tanks generally.
    • Trainers advise to blow the whole extinguisher even if flames aren’t visible to prevent auto-ignition.
    • You really, really want a hose on any extinguisher. Invert the extinguisher to get under a car/cabinet/low obstacle and the extinguisher is useless as the pressurized gas escapes, leaving behind the powder/foam/water that actually stops fire.
  • grueEnglish
    arrow-up
    18
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    I have four fire extinguishers:

    • One in the kitchen
    • One in the basement
    • One in my office (where I do stuff like soldering and 3D-printing)
    • One mounted to the roll bar of my Miata (I ought to get some for my other cars, but haven’t gotten around to making mounting brackets yet)

    However, I never would’ve thought to check them (or turn them upside down to “fluff” them) without this post, so thanks!

  • SickDisturbenceEnglish
    arrow-up
    18
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    As a gift to my friends who were going to be first time parents, I bought them a pack and play, a first aid kit, and a fire extinguisher. They laughed at my fire extinguisher gift and told their other friends who also laughed.

    • FireTowerOP
      arrow-up
      16
      arrow-down
      0
      ·
      9 months ago
      edit-2
      9 months ago
      link
      fedilink

      Laugh all they want burning alive is a shit way to go. And you might have saved them from that fate.

      • EmpricornEnglish
        arrow-up
        2
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        Just to be pedantic, I think most people who die in building fires perish due to smoke inhalation. Still bad though, and almost completely preventable!

    • Uranium 🟩
      arrow-up
      7
      arrow-down
      1
      ·
      9 months ago
      link
      fedilink

      Awh, that’s kind of crappy. I’m hoping they just took it as a gag gift; be prepared for anything, a bit like Jack Jack in The Incredibles.

      I hope theynever have to use it, but I hope they do learn how important it is.

      Same for cleaning dryer lint; before I was born the entire family who lived across the road from my mum perished in a house fire from dryer lint catching.

      Also add Carbon monoxide detectors to that list of devices you never want to need, but should never be without

      • wrekone
        arrow-up
        3
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        Dryer lint fires are so strange to me. Cleaning out the lint trap takes less than 5 seconds, and I do it with every load. I pulled the dryer hose off last weekend to clean it, and it was spotless, presumably because I clean the lint from the trap.

  • seaQueue
    arrow-up
    15
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Followed by: do you have a functional fire extinguisher in your kitchen and can you reach it immediately?

    Stove top fires are usually easy, just put a lid on whatever to put them out, but there’s always going to be someone who panics and dumps water on a grease fire.

    • Kelsenellenelvial
      arrow-up
      6
      arrow-down
      0
      ·
      9 months ago
      edit-2
      9 months ago
      link
      fedilink

      Not too immediately. Take 3 steps back/towards the nearest exit, that’s where you want the extinguisher. Not right next to the stove that’s going to be on fire when you need to get to the extinguisher.

      Keep in mind that a standard ABC extinguisher isn’t rated for grease fryers. If it’s just the fat needed to sautee something you’re good, but for an actual deep frying fire you want something in class K.

  • catonwheels
    arrow-up
    13
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Absolutely it is one of these products that you probably never need. But when you do you are so happy you had it standing around.

    I do routine inspections once a year when I do my fire alarm testing so every time I switch to daylight saving time.

    • chatokun
      arrow-up
      5
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Just caused an oil fire last week and fortunately it was working. I’ve since replaced also.

  • WhiteRabbit_33
    arrow-up
    10
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Those years of safety training finally paying off:

    Do you know what types of fires your fire extinguisher is rated for? There are several different types. Most modern home fire extinguishers are rated for A (wood/paper), B (liquids like oil fires), and C (electrical), but you may have an older fire extinguisher or landlord who cheaped out on one that only works on some of those types.

    If you have a fire that’s based on metals (like fireworks) or exothermic chemical reactions, have a different fire extinguisher or call the fire department with special instructions.

    Always remember the acronym PASS when using a fire extinguisher:

    1. Pull the pin
    2. Aim at the base of the fire
    3. Squeeze the trigger
    4. Sweep the fire extinguisher side to side to cover all of the fire till the fire is extinguished
    • wjrii
      arrow-up
      11
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      If you have a fire that’s based on metals (like fireworks) or exothermic chemical reactions, have a different fire extinguisher or call the fire department with special instructions.

      It ought to go without saying, but maybe not for some, so it’s worth pointing out that there’s a difference between a fire started by fireworks and one fueled by fireworks.

      • WhiteRabbit_33
        arrow-up
        4
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        Great point! So if you have a firework that sparks some dry grass or brush, your home fire extinguisher will likely be fine as long as the fire doesn’t get too big before you can grab it.

        However, if you have a hoard of fireworks that catch fire, you’re better off running and calling the fire department than trying to quickly put that out with your home fire extinguisher as it likely won’t work.

    • SkybreakerEngineerEnglish
      arrow-up
      4
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      My extensive training has left me with the impression that yelling SHORT BURST and pointing at any red LEDs is equally important

  • raptirEnglish
    arrow-up
    9
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Yup. We had one but after we had a smouldering fire in our outdoor trash can we got several for different points in the house. We also have escape ladders in the bedrooms.

    • girl
      arrow-up
      6
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      After being directly adjacent to three separate apartment fires, we also have several fire extinguishers and escape ladders stashed around the apartment.

  • Kalash
    arrow-up
    9
    arrow-down
    1
    ·
    9 months ago
    link
    fedilink

    Nope, don’t even have a fire alarm.

    • slazer2auEnglish
      arrow-up
      14
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      I am sure the insurance company loves you.

      • Track_ShovelEnglish
        arrow-up
        15
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        Falls asleep with a cigarette in his mouth every night

        • FireTowerOP
          arrow-up
          4
          arrow-down
          0
          ·
          9 months ago
          link
          fedilink

          Got to make sure you put a lit candle down on top of your oil soaked news papers. Otherwise they’ll blow away.

      • Kalash
        arrow-up
        6
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        I don’t remember them even asking for either one.

        • NuXCOM_90Percent
          arrow-up
          5
          arrow-down
          0
          ·
          9 months ago
          link
          fedilink

          That tends to be covered by code.

          if ANYTHING happens in your home and they either send someone out or a responder makes a note of it, you get dropped and they laugh.

          • Kalash
            arrow-up
            6
            arrow-down
            0
            ·
            9 months ago
            edit-2
            9 months ago
            link
            fedilink

            Yup, but neither is required by code where I live.

            Some insuraners offer a small discount for having a fire alarm, but they can’t drop you for not having one.

            • papalonian
              arrow-up
              2
              arrow-down
              0
              ·
              9 months ago
              link
              fedilink

              So it’s not my business but I’m curious You can get smoke detectors for like $10/each, you seen to acknowledge that having 0 smoke detectors is kinda dangerous why not install a couple smoke detectors? I always thought they were annoying until a Chinese cheap battery self ignited in the next room while I was sleeping, it would’ve burned my apartment building down if there wasn’t a smoke detector in the room.

              • Kalash
                arrow-up
                2
                arrow-down
                0
                ·
                9 months ago
                edit-2
                9 months ago
                link
                fedilink

                I used to live in Germany where smoke detectors where mandatory at some point. It was also the landlords responsibility. So what you had was a some company coming into your home once a year to check all the smoke detectors. I found that to be very intrusive.

                Not sure of this process has been digitised since (in Germany probably not), but I don’t really miss it. (I live in Switzerland now, and here smoke detectors are not required by anyone (might depend on Canton)).

                • papalonian
                  arrow-up
                  3
                  arrow-down
                  0
                  ·
                  9 months ago
                  link
                  fedilink

                  You don’t need anyone to come inspect anything. It’s literally a small plastic device you can buy online or at a store, put a battery in, and forget it exists until it tells you it needs a new battery or it saves your life.

                  When it’s required and the landlord’s responsibility, they’re liable if a fire happens and the detectors don’t do their job. So they’re gonna send someone out periodically to make sure it’s still functioning properly. There’s nobody there to check yours if you just buy your own.

                  Seriously, if that’s your only hold up, please get some smoke detectors in your house. Having smoke detectors isn’t something that you “miss”, it’s something that you hope you never have to have needed but the one time you do need it, it can save your life, your loved one’s lives, everything you own.

  • CoreidanEnglish
    arrow-up
    8
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Fire blankets are good to have as well

  • HelixDab2
    arrow-up
    7
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    Currently have 6. I need to get more, and larger ones. We live in a log house, in an area that takes a minimum of 20 minutes for emergency services to get to, and heat with a wood stove. We absolutely need to practice fire safety all the time.

    • nick
      arrow-up
      3
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Oh man, definitely get more!

      • HelixDab2
        arrow-up
        5
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        That’s the idea. The really big ones get pretty expensive though; a 30# fire extinguisher starts at around $500, and can get up to about $1500. But that size gets you about 20-30 seconds of continuous use, which is enough for a pretty big house fire.

  • Dem BosainEnglish
    arrow-up
    7
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    I have one that’s over 20 years old and it still shows proper pressure. I haven’t tested it, but I have replaced it.

    I should start a fire

    • FireTowerOP
      arrow-up
      7
      arrow-down
      0
      ·
      9 months ago
      link
      fedilink

      Some times being able to start a fire is just as important for survival as putting one out.

      • LazaroFilmEnglish
        arrow-up
        3
        arrow-down
        0
        ·
        9 months ago
        link
        fedilink

        My SO is really good at starting fires. She just says something, then stops and says never mind. Works every time.

  • earmuff
    arrow-up
    7
    arrow-down
    0
    ·
    9 months ago
    link
    fedilink

    I don’t use permanently pressurized fire extinguishers anymore, as they are hard to maintain and rarely reach a life span of 20 years.

    Make sure to check at least once every 3 years if the pressure is still in the green. If not, replace it immediately.

      • earmuff
        arrow-up
        5
        arrow-down
        1
        ·
        9 months ago
        link
        fedilink

        If you look at the gauge, you can see that the ideal pressure is 1344 kPa or 13.44 bar. If you own a pump capable of using at least 14 bar, you are good to go.